Scanning-fluorescence Reader Based on Embedded System
Scanning-fluorescence Reader Based on Embedded System
Journal from gdlhub / 2016-11-16 02:21:44By : Zhonglong Zhao, Xiaoping Min, Shengxiang Ge, Ningshao Xia, Telkomnika
Created : 2015-09-01, with 1 files
Keyword : fluorescence test strip, time-resolved fluoroimmunoassay, embedded system, scanningfluorescence reader
Url : http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/1808
To measure the concentration of C-reactive protein (CRP) in serum, a portable, scanning-fluorescence reader based on time-resolved fluoroimmunoassays was developed. The scanning-fluorescence reader integrates with the AD7707 converter, which performs at a high accuracy. The photosensitive diode acts as the photoelectric conversion device, an optical module based on optical fibers, which is able to concentrate the excitation light from an LED into a line-shape beam, was designed to sendand receive the optical signal. The device subsequently addresses waveform data using a gradient, smoothing, and binarization method. When the device measures the CRP fluorescence test strip, the results exhibited a good linearity (0.99998) and the CVs (coefficient of variation) were below 5%, which indicate high accuracy. At the same time the system is low cost and small size.
To measure the concentration of C-reactive protein (CRP) in serum, a portable, scanning-fluorescence reader based on time-resolved fluoroimmunoassays was developed. The scanning-fluorescence reader integrates with the AD7707 converter, which performs at a high accuracy. The photosensitive diode acts as the photoelectric conversion device, an optical module based on optical fibers, which is able to concentrate the excitation light from an LED into a line-shape beam, was designed to sendand receive the optical signal. The device subsequently addresses waveform data using a gradient, smoothing, and binarization method. When the device measures the CRP fluorescence test strip, the results exhibited a good linearity (0.99998) and the CVs (coefficient of variation) were below 5%, which indicate high accuracy. At the same time the system is low cost and small size.
Property | Value |
---|---|
Publisher ID | gdlhub |
Organization | Telkomnika |
Contact Name | Herti Yani, S.Kom |
Address | Jln. Jenderal Sudirman |
City | Jambi |
Region | Jambi |
Country | Indonesia |
Phone | 0741-35095 |
Fax | 0741-35093 |
Administrator E-mail | elibrarystikom@gmail.com |
CKO E-mail | elibrarystikom@gmail.com |
Print ...
Contributor...
- , Editor: sukadi
Downnload...
Download for member only.
1808-5078-1-PB
File : 1808-5078-1-PB.pdf
(434152 bytes)