Scanning-fluorescence Reader Based on Embedded System

Scanning-fluorescence Reader Based on Embedded System

Journal from gdlhub / 2016-11-16 02:21:44
By : Zhonglong Zhao, Xiaoping Min, Shengxiang Ge, Ningshao Xia, Telkomnika
Created : 2015-09-01, with 1 files

Keyword : fluorescence test strip, time-resolved fluoroimmunoassay, embedded system, scanningfluorescence reader
Url : http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/1808

To measure the concentration of C-reactive protein (CRP) in serum, a portable, scanning-fluorescence reader based on time-resolved fluoroimmunoassays was developed. The scanning-fluorescence reader integrates with the AD7707 converter, which performs at a high accuracy. The photosensitive diode acts as the photoelectric conversion device, an optical module based on optical fibers, which is able to concentrate the excitation light from an LED into a line-shape beam, was designed to sendand receive the optical signal. The device subsequently addresses waveform data using a gradient, smoothing, and binarization method. When the device measures the CRP fluorescence test strip, the results exhibited a good linearity (0.99998) and the CVs (coefficient of variation) were below 5%, which indicate high accuracy. At the same time the system is low cost and small size.

Description Alternative :

To measure the concentration of C-reactive protein (CRP) in serum, a portable, scanning-fluorescence reader based on time-resolved fluoroimmunoassays was developed. The scanning-fluorescence reader integrates with the AD7707 converter, which performs at a high accuracy. The photosensitive diode acts as the photoelectric conversion device, an optical module based on optical fibers, which is able to concentrate the excitation light from an LED into a line-shape beam, was designed to sendand receive the optical signal. The device subsequently addresses waveform data using a gradient, smoothing, and binarization method. When the device measures the CRP fluorescence test strip, the results exhibited a good linearity (0.99998) and the CVs (coefficient of variation) were below 5%, which indicate high accuracy. At the same time the system is low cost and small size.

Give Comment ?#(0) | Bookmark

PropertyValue
Publisher IDgdlhub
OrganizationTelkomnika
Contact NameHerti Yani, S.Kom
AddressJln. Jenderal Sudirman
CityJambi
RegionJambi
CountryIndonesia
Phone0741-35095
Fax0741-35093
Administrator E-mailelibrarystikom@gmail.com
CKO E-mailelibrarystikom@gmail.com

Print ...

Contributor...

  • , Editor: sukadi

Downnload...