This paper aims to clarify the optimum amount of fumed silica (SiO2) nanofiller in resisting

the initiation and propagation of electrical treeing in silicone rubber (SiR). Unlike other works, SiR/SiO2

nanocomposites containing seven different weight percentages of SiO2 nanofiller were prepared for this

purpose. To achieve the objective, the electrical tree characteristics of the SiR/SiO2 nanocomposites were

investigated by comparing the tree initiation voltage, tree breakdown time, tree propagation length and tree

growth rate with its equivalent unfilled SiR. Moreover, the structural and morphological analyses were

conducted on the SiR/SiO2 nanocomposite samples. The results showed that the SiR, when added with an

appropriate amount of SiO2 nanofiller, could result in an improved electrical tree resistance. It implies that

the 5 wt% of silica is the optimum amount to achieve the optimal electrical tree resistance such that above

5 wt%, the tree resistance performance has been abruptly reduced, subjected to the agglomeration issue.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID Publishergdlhub
OrganisasiTelkomnika
Nama KontakHerti Yani, S.Kom
AlamatJln. Jenderal Sudirman
KotaJambi
DaerahJambi
NegaraIndonesia
Telepon0741-35095
Fax0741-35093
E-mail Administratorelibrarystikom@gmail.com
E-mail CKOelibrarystikom@gmail.com

Print ...

Kontributor...

  • , Editor: sukadi

Download...