Makalah ini menyajikan model pembangkit energi terbarukan terdistribusi (RDG) tiga fase dalam perhitungan aliran daya dan analisis pengaruhnya ketika terhubung dalam sistem gabungan. Model RDG yang telah dibahas terdiri dari fotovoltan (PV) dan pembangkit turbin angin (WTG). Simpul kendali tegangan dan simpul injeksi daya komplek digunakan dalam pemodelan pembangkit. Pengembangan ini sesuai untuk aplikasi pada analisis sistem daya grid cerdas. Kombinasi data transmisi dan distribusi IEEE digunakan untuk menguji algoritma dalam masalah sistem distribusi tiga fase kondisi seimbang dan tidak seimbang. Hasil simulasi menunjukkan bahwa peningkatan jumlah dan ukuran RDG telah memperbaiki profil tegangan dan mengurangi rugi-rugi
Deskripsi Alternatif :The paper presents renewable distributed generation (RDG) models as three-phase resource in load flow computation and analyzes their effect when they are connected in composite networks. The RDG models that have been considered comprise of photovoltaic (PV) and wind turbine generation (WTG). The voltage-controlled node and complex power injection node are used in the models. These improvement models are suitable for smart grid power system analysis. The combination of IEEE transmission and distribution data used to test and analyze the algorithm in solving balanced/unbalanced active systems. The combination of IEEE transmission data and IEEE test feeder are used to test the the algorithm for balanced and unbalanced multi-phase distribution system problem. The simulation results show that by increased number and size of RDG units have improved voltage profile and reduced system losses.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | gdlhub |
Organisasi | Telkomnika |
Nama Kontak | Herti Yani, S.Kom |
Alamat | Jln. Jenderal Sudirman |
Kota | Jambi |
Daerah | Jambi |
Negara | Indonesia |
Telepon | 0741-35095 |
Fax | 0741-35093 |
E-mail Administrator | elibrarystikom@gmail.com |
E-mail CKO | elibrarystikom@gmail.com |
Print ...
Kontributor...
- , Editor: sukadi
Download...
Download hanya untuk member.
1152-1885-1-SM
File : 1152-1885-1-SM.pdf
(190481 bytes)