Path: Top -> Journal -> Jurnal Nasional Teknik Elektro dan Teknologi Informasi -> 2013 -> Vol 2, No 1 (2013)
Analisis Perubahan Parameter Number of Signals Averaged (NSA) Terhadap Peningkatan SNR dan Waktu Pencitraan pada MRI
Analisis Perubahan Parameter Number of Signals Averaged (NSA) Terhadap Peningkatan SNR dan Waktu Pencitraan pada MRI
Journal from gdlhub / 2016-10-31 06:35:42Oleh : Dwi Rochmayanti, Thomas Sri Widodo, Indah Soesanti, JNTETI
Dibuat : 2013-02-01, dengan 1 file
Keyword : NSA, SNR, Sekuens Spin echo, citra dengan pembobotan T1, waktu pencitraan
Url : http://ejnteti.jteti.ugm.ac.id/index.php/JNTETI/article/view/26
Telah dilakukan penelitian perubahan NSA terhadap SNR yang bertujuan untuk mengetahui pengaruh perubahan NSA terhadap SNR. Penelitian dilakukan di RS Telogorejo Semarang dengan Modalitas MRI Airis II Hitachi 0,3 tesla, dengan cara merubah NSA 1 sampai dengan 5 pada daerah leher (servikal) dengan potongan sagital dengan sekuens spin echo dan pembobotan T1. Dari citra tersebut dicari nilai intensitas dan noise untuk mendapatkan SNR pada masing-masing citra. ROI pada daerah korpus, medulla spinalis dan diskus intervertebra untuk mendapatkan signal rata-rata untuk dibandingkan dengan ROI pada background. Dari penelitian didapatkan hasil, semakin besar NSA yang digunakan SNR juga semakin meningkat. Prosentase kenaikan rata-rata dari badan vertebra (corpus), medulla spinalis dan diskus intervertebra adalah dari NSA 1 ke 2 adalah 51%, NSA dinaikkan menjadi 3 prosentase kenaikan 86%, NSA 4 kenaikannya 99% dan NSA 5 menjadi 102%. Untuk mendapatkan SNR mendekati 100%, maka NSA yang digunakan adalah 4. Sedangkan untuk mencari citra dengan SNR yang baik dan waktu pencitraan yang tidak lama, sebaiknya digunakan NSA 3.
Deskripsi Alternatif :A study about the influence of NSA shift to SNR to identify the existence of NSA shift to SNR and scan time had performed. The study aims to determine the alteration value of SNR when NSA was changed for every number and to obtain the NSA value which has more optimum image quality. The study was performed in Telogorejo Hospital at Semarang with MR modalities AirisII Hitachi 0.3 tesla by shifting NSA from 1 to 5 in cervical vertebrae (neck) sagittal T1 weighted with spin echo sequence. The SNR of five images were calculated with Matlab tool. SNR value was obtained by measuring the ROI at body of vertebra, spinal cord area and discus intervertebra to attain the signal average value. Experiment results show that the greater the NSA, the SNR is better and scan time is longer. SNR of the organ corpus, medulla spinalis and diskus intervertebra is increases from NSA 1 to 2 is 51%. When the NSA is raised to 3, the SNR increase is 89%, for NSA 4 the SNR increase is 99%, for NSA 5 the SNR increase is 102% . To get an SNR up to 100%, the NSA 4 is used. Meanwhile, to get images with good SNR and imaging duration is not long, the NSA 3 is used.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | gdlhub |
Organisasi | JNTETI |
Nama Kontak | Herti Yani, S.Kom |
Alamat | Jln. Jenderal Sudirman |
Kota | Jambi |
Daerah | Jambi |
Negara | Indonesia |
Telepon | 0741-35095 |
Fax | 0741-35093 |
E-mail Administrator | elibrarystikom@gmail.com |
E-mail CKO | elibrarystikom@gmail.com |
Print ...
Kontributor...
- , Editor: Calvin
Download...
Download hanya untuk member.
26-107-1-PB
File : 26-107-1-PB.pdf
(1057428 bytes)