Path: Top -> Journal -> Telkomnika -> 2017 -> Vol.15, No.3, September

Development of Ammonia Gas Leak Detection and Location Method

Journal from gdlhub / 2017-11-07 12:46:12
Oleh : Ding Xibo, Wang Ru-yue, Telkomnika
Dibuat : 2017-11-07, dengan 1 file

Keyword : ammonia; Gaussian model; location of leakage source; wireless sensor network
Url : http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/5079
Sumber pengambilan dokumen : WEB

This paper proposed the gas for industrial ammonia leak diffusion model and the Gauss method of leakage localization. A set of wireless ammonia leak alarm system is composed of sensor node, network coordinator and host used in the industrial field was developed, the purpose is to reduce the loss of property caused by the leakage of ammonia industry. Using the monitoring system to carry out the ammonia leak location simulation measurement experiment, the result shows that the relative positioning error of the monitoring system is about 12%, which meets the needs of industrial production safety monitoring. Using the wireless sensor network to monitor the concentration of ammonia gas and locate the leakage source, it solves the problems of traditional wired alarm system, such as difficult wiring and weak expansibility, which helps to find the leak timely and provides a reference for the emergency rescue work.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID Publishergdlhub
OrganisasiTelkomnika
Nama KontakHerti Yani, S.Kom
AlamatJln. Jenderal Sudirman
KotaJambi
DaerahJambi
NegaraIndonesia
Telepon0741-35095
Fax0741-35093
E-mail Administratorelibrarystikom@gmail.com
E-mail CKOelibrarystikom@gmail.com

Print ...

Kontributor...

  • , Editor: sukadi

Download...