Path: Top -> Journal -> Telkomnika -> 2016 -> Vol 14, No 2: June
Delta-Polygon Autotransformer Based 24-Pulse Rectifier for Switching Mode Power Supply
Delta-Polygon Autotransformer Based 24-Pulse Rectifier for Switching Mode Power Supply
Journal from gdlhub / 2016-11-07 03:37:39Oleh : Chun-ling Hao, Xiao-qiang Chen, Hao Qiu, Telkomnika
Dibuat : 2016-06-01, dengan 1 file
Keyword : autotransformer; multipulse rectifier; harmonic mitigation; power quality
Url : http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/2652
In medium and high power capacity switching mode power supply (SMPS), power quality at the AC side is often severely distorted. In this paper, a small magnetic rating delta-polygon autotransformer based 24-pulse rectifier feeding SMPS is designed, constructed, and simulated for harmonic mitigation. Various auto-wound transformers for the 24-pulse AC-DC converter are discussed and compared in terms of magnetic rating and power quality indices, in order that the optimal autotransformer structure can be chosen. The effect of load variation on the proposed 24-pulse rectifier is also analyzed. Moreover, performance of the 6-, 12-, and 18-pulse rectifiers based on delta-polygon autotransformer are studied through comparison. Results demonstrate that the total harmonic distortion of utility current is lower than 6.10% and unity power factor is achieved under varying load.
In medium and high power capacity switching mode power supply (SMPS), power quality at the AC side is often severely distorted. In this paper, a small magnetic rating delta-polygon autotransformer based 24-pulse rectifier feeding SMPS is designed, constructed, and simulated for harmonic mitigation. Various auto-wound transformers for the 24-pulse AC-DC converter are discussed and compared in terms of magnetic rating and power quality indices, in order that the optimal autotransformer structure can be chosen. The effect of load variation on the proposed 24-pulse rectifier is also analyzed. Moreover, performance of the 6-, 12-, and 18-pulse rectifiers based on delta-polygon autotransformer are studied through comparison. Results demonstrate that the total harmonic distortion of utility current is lower than 6.10% and unity power factor is achieved under varying load.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | gdlhub |
Organisasi | Telkomnika |
Nama Kontak | Herti Yani, S.Kom |
Alamat | Jln. Jenderal Sudirman |
Kota | Jambi |
Daerah | Jambi |
Negara | Indonesia |
Telepon | 0741-35095 |
Fax | 0741-35093 |
E-mail Administrator | elibrarystikom@gmail.com |
E-mail CKO | elibrarystikom@gmail.com |
Print ...
Kontributor...
- , Editor: sukadi
Download...
Download hanya untuk member.
2652-8493-1-PB
File : 2652-8493-1-PB.pdf
(1044957 bytes)