Path: Top -> Journal -> Jurnal Nasional Teknik Elektro dan Teknologi Informasi -> 2014 -> Vol 3, No 2 (2014)
Pengujian Modul Monitor Radiasi Pada Sistem Pemantauan Pengangkutan Zat Radioaktif
Pengujian Modul Monitor Radiasi Pada Sistem Pemantauan Pengangkutan Zat Radioaktif
Journal from gdlhub / 2016-11-01 02:16:23Oleh : Adi Abimanyu, JNTETI
Dibuat : 2014-05-01, dengan 1 file
Keyword : Radiation, monitor, conversion factors, chi square test
Url : http://ejnteti.jteti.ugm.ac.id/index.php/JNTETI/article/view/72
Sistem monitor radiasi atau yang banyak dikenal sebagai surveymeter telah banyak digunakan untuk memonitor laju paparan radiasi dengan memanfaatkan detektor untuk mendeteksi pulsa radiasi yang dihasilkan oleh zat radioaktif. Penelitian ini difokuskan pada pengujian modul monitor radiasi yang digunakan pada sistem pemantau pengangkutan zat radioaktif. Kestabilan modul diuji dengan chi square test dengan sumber standar Cs-137 dilakukan sebanyak 20 data, pengujian jangkauan pengukuran alat dilakukan dengan cara memberikan pulsa standar dari pembangkit pulsa dengan frekuensi dari 1 sampai dengan frekuensi 327 kHz sebagai pengganti sumber radiasi dan faktor konversi cps ke mR/jam dilakukan dengan membandingkan hasil pengukuran dengan alat standar. Dari hasil pengujian penelitian ini didapatkan harga stabilitas cacah latar 15,54 dan cacah dengan sumber 19,76 serta berada dalam rentang 11,7 ≤ x2 ≤ 27,2 Sehingga sistem ini dapat diterima dan telah berfungsi dengan baik. Sedangkan faktor konversi cps ke mR/jam adalah 0,058 mR/jam.cps sehingga jangkauan pengukuran radiasi modul monitor radiasi ini adalah 0,058mR/jam sampai dengan 18,98960 R/jam.
Deskripsi Alternatif :Radiation monitor system or widely known as surveymeter has been widely used to monitor the rate of radiation exposure by utilizing detector to detect radiation pulses generated by radioactive substances. This study focused on testing the radiation monitor module used in the system of monitoring the transport of radioactive substances. The stability of the module was tested by chi square test with a standard source of Cs-137 performed a total of 20 data measurement range test instrument is done by providing a standard pulse from the pulse generator with a frequency of 1 to 327 kHz frequency as a substitute source of radiation and cps conversion factor to mR / h is done by comparing the results of measurements with standard tools. From the results of this study, the value of testing the stability of the background count 15.54 and the count value with 19.76 sources and within the range of 11,7 ≤ c2≤ 27,2 So this system is acceptable and has been functioning properly. While the conversion factor cps to mR / hr is 0.058 mR / jam.cps so the range radiation module is 0.058 mR / hr up to 18.98960 R / hour.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | gdlhub |
Organisasi | JNTETI |
Nama Kontak | Herti Yani, S.Kom |
Alamat | Jln. Jenderal Sudirman |
Kota | Jambi |
Daerah | Jambi |
Negara | Indonesia |
Telepon | 0741-35095 |
Fax | 0741-35093 |
E-mail Administrator | elibrarystikom@gmail.com |
E-mail CKO | elibrarystikom@gmail.com |
Print ...
Kontributor...
- , Editor: sukadi
Download...
Download hanya untuk member.
72-85-1-PB
File : 72-85-1-PB.pdf
(385722 bytes)