Generator fluks aksial rotor belitan mempunyai belitan medan yang dihubungkan dengan sumber tegangan dc. Dengan mengatur tegangan eksitasi, maka unjuk kerjanya dapat diatur untuk memenuhi kebutuhan tegangan beban yang terpasang pada terminalnya. Generator yang dirancang berkapasitas skala kecil yang mempunyai1 kW, 380 V and 750 rpm. Generator mempunyai satu stator belitan dua sisi beralur yang diapit oleh rotor kembar. Pengaruh perubahan tegangan eksitasi terhadap unjuk kerja dapat dilihat dari hasil perhitungan yang menggunakan persamaan-persamaan. Hasil-hasil perhitungan menunjukkan besaran listrik telah memenuhi unjuk kerja mesin. Semakin tinggi tegangan eksitasi, semakin rendah rugi-ruginya sedangkan efisiensi dan tegangan terminal semakin tinggi. Telah diperoleh bahwa untuk tegangan eksitasi 11 V, maka efisiensi dan tegangan terminalnya masing-masing 85,12 % and 380 V.

Deskripsi Alternatif :

The axial flux wound rotor generator has field winding that must be connected to a dc voltage source. By varying the excitation voltage, its electric performance might be controlled to meet the need of a load voltage attached to its terminal. The designed generator is small-scale capacity which has 1 kW, 380 V and 750 rpm. The generator has a single double-sided slotted wound stator sandwiched between twin rotor. The effect of excitation voltage changes on its performance can be seen from the result of calculations using the given equations. The calculation results reveal electric quantities suited with respect to performance of the machine. If the voltages increase, the losses will decrease; but higher the excitation voltage, higher the efficiency and the terminal voltage. It has been found out that for the excitation voltage11 V, the efficiency and the terminal voltage are 85.12 % and 380V respectively.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID Publishergdlhub
OrganisasiTelkomnika
Nama KontakHerti Yani, S.Kom
AlamatJln. Jenderal Sudirman
KotaJambi
DaerahJambi
NegaraIndonesia
Telepon0741-35095
Fax0741-35093
E-mail Administratorelibrarystikom@gmail.com
E-mail CKOelibrarystikom@gmail.com

Print ...

Kontributor...

  • , Editor: sukadi

Download...

  • Download hanya untuk member.

    926-1499-1-SM
    Download Image
    File : 926-1499-1-SM.pdf

    (356508 bytes)